Syrex

Dsp Sine Wave Inverter / Ups

We have developed Inverter, HUPS, from 300VA to 5KVA Single phase with below features:-

  • Best designed for energy savings and suitable for frequent power fluctuations
  • Output waveform: Pure sine wave
  • Frequency: 50Hz±1%,
  • Unique “DSP Technology” zero humming of electrical & electronic products
  • Battery Gravity Builder with overcharge and deep discharge protections
  • Less energy consumption in a year as compared to any other brand
  • Selectable charging mode for different battery technologies (Flat/Tubular battery) and capacities (100 Ah to 250 Ah) using selector switch
  • 10-15% higher back up than any other competitor brands
  • Runs juicer/ Mixer Grinder easily up to 900W rating
  • Charges battery from as low as 70V mains
  • Enhanced Temperature Protection.
  • Safety :- MCB for protection from Input main
SKU SYTT 26060 Categories ,

Specifications:-

PARAMETERS MODELS column_3 column_4 column_5 column_6 column_7 column_8
Model R925/12V R1125/12V R1325/12V R1825/24V R2225/24V R2625/24V R3725/48V
No Load Current ≤ 2.0A ≤ 2.5A ≤ 2.5A
Output Voltage @ No Load ≤ 240VAC @12.0VDC ≤ 240VAC @24.0VDC ≤ 240VAC @48.0VDC
Battery Current @ Full Load 44A ±2A 54A ±2A 64A ±2A 54A ±2A 64A ±2A 75A ±2A 60A ±2A
Over Load Alarm 46A ±2A 56A ±2A 66A ±2A 56A ±2A 66 ±2A 77A ±2A 62A ±2A
Battery Low Alarm 10.6 ±0.2V 21.2 ±0.2V 21.2 ±0.2V 21.2 ±0.2V 42.4 ±0.2V
Battery Low Shutdown 10.4 ±0.2V 20.8 ±0.2V 20.8 ±0.2V 20.8 ±0.2V 41.6 ±0.2V
Short Circuits Protection Yes
Inverter Output Frequency 50 ± 0.1 Hz
UPS MODE
Mains Input Voltage Range 170V To 265V
Mains AC Low Cut 170VAC ±10VAC
Mains AC Low Cut Recovery 180VAC ±10VAC
Mains AC High Cut 265VAC ±10VAC
Mains AC High Cut Recovery 255VAC ±10VAC
Maximum Change Over Time <8msec
W-UPS MODE
Mains Input Voltage Range 90V To 290V
Mains AC Low Cut 90VAC ±10VAC
Mains AC Low Cut Recovery 110VAC ±10VAC
Mains AC High Cut 290VAC ±10VAC
Mains AC High Cut Recovery 280VAC ±10VAC
Maximum Change Over Time <20msec
CHARGING MODE
Charging Current@220VAC 15.0 ±2A
Boost Voltage (Tub Mode ) 14.4V ±0.2V 28.8V ±0.4V 57.6V ±0.8V
Boost Voltage (LA Mode ) 14.0V ±0.2V 28.0V ±0.4V 56V ±0.8V
Boost Mode ( Enable Tub Mode) 15.0V ±0.2V 30.0V ±0.4V 60.0V ±0.8V
Boost Mode ( Enable LA Mode) 15.0V ±0.2V 30.0V ±0.4V 60.0V ±0.8V
Float Voltage 13.6V ±0.2V 27.2V ±0.4V 54.4V ±0.8V
Short Circuit Yes
PROTECTION
Battery Low Cut Off 1 Time
Over Load (Auto Retries) 4 Times
Short Circuits (Auto Retries) 3 Times
Over Temperature 3 Times
Battery Over Charge Yes
Input Protection Yes (Mains Fuse Blown/MCB Trip in Case of Short Circuit in Mains Mode)

Service Request